incl. VAT plus shipping costs

Item no.: EPI-10052

Gap-filling two-component polyurethane adhesive

  • Gap-filling
  • Long open time
  • High strength in metal bonding
  • Good adhesion to copper and brass

Araldite® 2029-1 is a grey, pasty two-component polyurethane adhesive that cures at room temperature.
Araldite® 2029-1 is a higher-strength adhesive that is well suited for structural adhesive bonds. High strength on metals.

2K PUR polyurethane adhesive with a mixing ratio of 1:1
Colour (mixed)grey
Viscositythixotropic (pasty)
Processing time for 100 g at 23°C40 minutes
Handling strength at 23°C for TSS 1 N/mm²240 minutes
Tensile shear strength (TSS) on aluminium at 23°C25 N/mm²
E-modulus at 23°C580 N/mm²
Elongation at break at 23°C47 %
Roll peel test (ISO 4587) curing 16 h/40°C3,1 N/mm²
Maximum temperature leading to a TSS of 5 N/mm²80 °C

Packaging: 50 ml dual cartridge with static mixing nozzle
Item number: ARA-2029-50

Net weight: 0,05 kg

Product Safety Information
(As of 10/2018)

Signal word: Danger + Warning

Epoxidharze Andreas Weigel | Araldite® 2029-1 50 ml with Mixing Spindle
Epoxidharze Andreas Weigel | Araldite® 2029-1 50 ml with Mixing Spindle
Epoxidharze Andreas Weigel | Araldite® 2029-1 50 ml with Mixing Spindle
  • H302 Harmful if swallowed.
  • H304 May be fatal if swallowed and enters airways.
  • H315 Causes skin irritation.
  • H317 May cause an allergic skin reaction.
  • H319 Causes serious eye irritation.
  • H332 Harmful if inhaled.
  • H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.
  • H335 May cause respiratory irritation.
  • H351 Suspected of causing cancer.
  • H373 May cause damage to organs through prolonged or repeated exposure.
  • H373 May cause damage to organs through prolonged or repeated exposure if inhaled.
  • H400 Very toxic to aquatic life.
  • H410 Very toxic to aquatic life with long lasting effects.
  • H411 Toxic to aquatic life with long lasting effects.
  • P260 Do not breathe mist or vapour.
  • P264 Wash skin thoroughly after handling.
  • P273 Avoid release to the environment.
  • P280 Wear protective gloves / protective clothing / eye protection / face protection.
  • P304 + P340 + P312 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER / doctor if you feel unwell.
  • P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P308 + P313 IF exposed or concerned: Get medical advice / attention.
  • P337 + P313 If eye irritation persists: Get medical advice / attention.
  • P501 Dispose of contents / container at an approved waste disposal facility in accordance with local, regional, national and international regulations.